This file provides guidance to Claude Code (claude.ai/code) when working with code in this repository.
Common Development Commands
- Build:
make build- Compiles firmware for ESP32-C6 - Upload:
make upload- Flashes firmware to device (requires USB connection) - Test:
make test- Runs all unit/integration tests using Vitest - Single Test:
make test TEST_NAME="test_module_name"- Runs specific test - Debug:
make debug- Starts debug mode with serial console
Code Architecture
The system implements a layered architecture for AC controller control:
-
Zigbee Interface Module
- Receives and decodes Zigbee messages from Home Assistant or similar
- Translates commands to UART format
- Key files:
zigbee-handler.c,zigbee-decoder.h
-
Command Processing Core
- Implements MideaUART protocol (based on cloned MideaUART repository)
- Parses UART commands and converts to AC control signals
- Key files:
uart-controller.c,midea-parser.h
-
Hardware Abstraction Layer
- Manages ESP32-C6 GPIO and UART operations
- Handles precise timing for AC communication protocol
- Key files:
hardware-abstraction.c
Development Notes
- Protocol implementation must strictly follow MideaUART specifications
- UART communication requires 50ms baud rate timing
- Testing should focus on edge cases for time-sensitive operations
- Dependencies managed via Makefile - do not modify directly
- MideaUART implementation: https://github.com/dudanov/MideaUART
Zigbee ZCL HVAC Integration (Thermostat Cluster)
1. Core Zigbee Cluster Attributes
local_temperature(int16_t): Current measured temperature (0.01°C resolution)system_mode(uint8_t): Current system mode- 0x00: Off, 0x01: Auto, 0x03: Cooling, 0x04: Heating
- 0x08: Dry, 0x09: Sleep
local_temperature_display: Display temperature value for UI
2. HVAC System Types
- Supports standard HVAC modes: Cooling, Heating, Heat Pump (Cooling + Heating)
- Configuration constants:
EZB_ZCL_HVAC_SYSTEM_TYPE_CONFIGURATION_COOLING_SYSTEM_STAGE = 0x03
3. Temperature Control
- Temperature range: -1°C to 32767°C (0.01°C resolution)
- Convert to MideaUART format: divide by 100 (e.g., 2500 → 25.0°C)
- Command structure:
control.mode = MODE_COOL; // Zigbee mode: 0x03 (Cooling) control.targetTemp = 25.0f; // 25°C target control.modeChange = true; ac.control(control);
4. Schedule Management
- Support weekly schedule setting/clearing through Zigbee cluster commands
- Convert schedule entries to MideaUART Control scheduling parameters
5. Status Monitoring Integration
- Monitor
AlarmMaskfor hardware failures - Track
ACErrorCodefor system fault detection - Implement status callbacks for UI updates
6. Mapping Example
// When Zigbee reports mode = 0x03 (Cooling) and target temp = 2500 (25.00°C)
Control control;
control.mode = MODE_COOL;
control.targetTemp = 25.0f; // Convert from 0.01°C units
control.modeChange = true;
ac.control(control);
This documentation covers both the core Midea UART protocol for device communication and the Zigbee ZCL thermostat cluster integration for smart home control.