Home Assistant Integration Guide

This controller presents the Ballu AC to Home Assistant as a standard Zigbee ZCL Thermostat device. Home Assistant talks to it through a Zigbee coordinator running either ZHA or Zigbee2MQTT — no custom integration is needed beyond the device pairing.

1. What the Device Exposes

The firmware implements a ZCL Thermostat cluster server (src/zigbee_zcl.c) with these attributes:

ZCL attribute Type Meaning
local_temperature int16, 0.01°C Current indoor temperature read from the AC
system_mode uint8 Operating mode (see mapping below)

system_mode values (as exposed on the Zigbee side):

Value Mode
0 Off
1 Auto
3 Cool
4 Heat

Internally these map to MideaUART modes via the integration layer (integration_layer_map_zcl_to_midea_mode); MideaUART additionally supports Dry, Fan, Sleep, and Turbo (src/midea_protocol.h).

2. Pairing

  1. Put the Zigbee coordinator into permit-join mode (ZHA: Add device; Zigbee2MQTT: Permit join).
  2. Power on the ESP32-C6 controller; it joins as a Zigbee end device / router.
  3. The device appears with a Thermostat entity exposing current temperature and a mode selector.

3. Home Assistant Climate Entity

Once paired, ZHA/Zigbee2MQTT automatically create a climate.* entity backed by the Thermostat cluster. Example resulting entity state:

climate.ballu_ac:
  current_temperature: 24.5      # from local_temperature (2450 * 0.01°C)
  hvac_mode: cool                # from system_mode = 3
  temperature: 25.0              # target setpoint

Setting mode and temperature (Lovelace / service call)

# Turn on cooling at 25°C
service: climate.set_temperature
target:
  entity_id: climate.ballu_ac
data:
  hvac_mode: cool
  temperature: 25
# Switch to heating
service: climate.set_hvac_mode
target:
  entity_id: climate.ballu_ac
data:
  hvac_mode: heat
# Turn the unit off
service: climate.set_hvac_mode
target:
  entity_id: climate.ballu_ac
data:
  hvac_mode: "off"

4. Example Automations

Cool the room when it gets warm:

automation:
  - alias: "Cool bedroom when hot"
    trigger:
      - platform: numeric_state
        entity_id: climate.ballu_ac
        attribute: current_temperature
        above: 27
    action:
      - service: climate.set_temperature
        target:
          entity_id: climate.ballu_ac
        data:
          hvac_mode: cool
          temperature: 24

Turn the AC off when everyone leaves:

automation:
  - alias: "AC off when away"
    trigger:
      - platform: state
        entity_id: group.family
        to: "not_home"
    action:
      - service: climate.set_hvac_mode
        target:
          entity_id: climate.ballu_ac
        data:
          hvac_mode: "off"

5. Zigbee2MQTT Notes

If using Zigbee2MQTT, the device publishes to zigbee2mqtt/<friendly_name> with a JSON payload containing local_temperature and system_mode. Publish a command like:

{ "system_mode": "cool", "occupied_heating_setpoint": 2500 }

Setpoints in raw ZCL are in 0.01°C units (2500 = 25.0°C), matching the firmware's temperature representation.

6. Status Reporting & Faults

  • The controller polls the AC on a configurable interval (default 5000 ms, status_monitor_config_t.poll_interval_ms) and updates local_temperature / system_mode accordingly.
  • If the AC reports a non-zero error_code or alarm_mask, the status monitor latches a fault (status_monitor_has_fault) and the app controller reports unhealthy (app_controller_is_healthy).
  • A communication watchdog triggers automatic reset/recovery (app_controller_recover_if_needed) if polling fails repeatedly.

See docs/zcl_hvac.md for the full ZCL Thermostat cluster reference and docs/hardware_connection_diagram.md for wiring.